The A3 Adapter Connections
ConnectionsThe Adapter A3 is plugged in between the microphones and recording equipment. Please bear in mind that you should remove the microphone plug from the A3 Adapter after use. This is to avoid discharging the battery, since plugging the microphone activates the adapter which uses electricity. Low Frequency Roll OffThe switch position " /" is to be chosen when recording speech. This attenuates frequencies below 300Hz. The switch position "-" (linear) is chosen to record music. Linear AttenuationThe switch position "-20dB" is used when recording high sound pressure levels. For moderate SPLs, especially with the A3 on the LINE input, the switch position "0" is recommended. Battery CheckTo check the remaining battery capacity, press the test knob, which lights up the green LED. The brightness of the LED offers an indication of the remaining battery life time. If the LED extinguishes, please replace the battery. ExtensionWhen the microphone is placed at some distance from the recording equipment, the microphone cable can be extended, provided that the cable capacity does not exceed 1000 pF. Extending the adapter output cable is not recommended. |